Engineering FAQ · Wanlin
Cold Chain Locker Control Board Manufacturer | Canada Export
A: Four independent NTC sensor channels feed zone-specific control loops, so chilled, frozen and ambient sections each hold their set points while one Android interface manages pickup for all doors.
Direct answer
A: Four independent NTC sensor channels feed zone-specific control loops, so chilled, frozen and ambient sections each hold their set points while one Android interface manages pickup for all doors.
Executive Summary: Cold Chain Locker Control Board for Canada Market

Product Introduction: AndroidSBC Cold Chain Locker Control Board
Core Features:
- Lock Control and Connectivity: RS485 Modbus lock buses, door-status feedback, Gigabit Ethernet, WiFi and 4G LTE options
- Display Flexibility: LVDS, eDP, HDMI and MIPI-DSI outputs from 7 to 32 inch panels, portrait or landscape
Technical Specifications
| Parameter | AndroidSBC Specification |
|---|---|
| CPU | Rockchip RK3568, quad-core Cortex-A55 @ 2.0 GHz |
| Temperature zones | 4 independent NTC zones, chilled 0-4°C, frozen -18°C, ambient |
| Accuracy | ±0.5°C sensing with 10-second sampling |
| Cooling control | Compressor PWM, fan speed, defrost and drain-heat scheduling |
| Data logging | Local eMMC logs plus cloud sync, exportable audit reports |
| Alarms | Over-temperature SMS, email and app push, local buzzer |
| Lock control | RS485 Modbus, 24-door standard with status feedback |
| Display | LVDS/eDP touch panel for pickup interface |
| Network | Gigabit Ethernet, WiFi, 4G LTE optional, PoE supported |
| Reliability | -30°C to 70°C rated for freezer-side mounting, watchdog, RTC |
Application Scenarios for Canada Market
| Scenario | Recommended model | Key benefits |
|---|---|---|
| Frozen food lockers | AS-CC3568F (-18°C) | Freezer zones with defrost scheduling |
| Chilled grocery lockers | AS-CC3568R (0-4°C) | Multi-zone fresh pickup cabinets |
| Pharmacy pickup | AS-CC3568P (2-8°C) | Validated storage with audit trail |
| Flower and bakery | AS-CC3568B (8-15°C) | Gentle cooling for delicate goods |
Q: How does the board keep different temperature zones in one cabinet?
A: Four independent NTC sensor channels feed zone-specific control loops, so chilled, frozen and ambient sections each hold their set points while one Android interface manages pickup for all doors.
Q: What happens if a cooling zone drifts out of range?
A: The board raises over-temperature alarms immediately by SMS, email and app push, logs the event locally and to the cloud, and can lock out affected doors until temperatures recover.
Q: Can temperature records be exported for audits?
A: Yes. Logs are stored on eMMC and synchronized to the cloud CMS, exportable as CSV reports covering time, zone and temperature for cold-chain compliance audits.
Q: Does the board work inside the freezer compartment?
A: The extended-temperature variant is rated for -30°C to 70°C operation, suitable for freezer-side mounting with conformal coating against condensation.
Q: Is compressor control compatible with common refrigeration units?
A: PWM and relay outputs cover mainstream compressor and fan units, and wiring diagrams plus protocol documentation are provided for integration with existing cooling systems.
Project Summary
For more information: www.androidsbc.com | Export Service Hotline: +8613261677119 | Email: Androidsbc@163.com
- Shenzhen HQ: Wanlin Group, Building B, Building 1, Beisida Medical Device Building, 28 Nantong Avenue, Baolong Community, Baolong Sub-district, Longgang District, Shenzhen, Guangdong, China
Application fit
Confirm the operating environment, workload, display, network and peripheral requirements.
Documents to confirm
Check the exact board revision, interfaces, firmware build and certification scope.
Commercial confirmation
Verify quantity, sample plan, lead time, warranty and delivery terms in writing.